Leak Testers

ELT-201WP

Features
  • Meets USP specifications and packaging standards
  • 5.7 inch graphical touch screen display
  • Programmable vacuum level and hold time
  • Slow venting for better results
  • Validation report printout (Serial / LAN)
  • Oil-less vacuum pump
  • Weighing scale interface to get results
  • Tolerance range setting to give pass / fail results
  • Programmable 50 methods and storage of 50 product data
  • Embedded printer for printing reports
  • Ideal for checking leakage of packed strips, blisters, small sachets and ampoules
Specifications
Model ELT-201WP
Vacuum level 2 mmHg to 650 mmHg
Timer Maximum can be set up to 00.01 minutes
Minimum can be set up to 99.59 min
Vacuum setting level Vacuum can stabilize to the set value +5 mmHg within 90 secs
Power requirement 230V. 50Hz
Power 300 VA
Dimension
( W x L x H)
396 x 245 x 228

ELT-201P

Features
  • Meets USP specifications and packaging standards
  • 5.7 inch graphical touch screen display
  • Programmable vacuum level and hold time
  • Slow venting for better results
  • Validation report printout (Serial / LAN)
  • Oil-less vacuum pump
  • Weighing scale interface to get results
  • Tolerance range setting to give pass / fail results
  • Programmable 50 methods and storage of 50 product data
  • Embedded printer for printing reports
  • Ideal for checking leakage of packed strips, blisters, small sachets and ampoules
Specifications
Model ELT-201WP
Vacuum level 2 mmHg to 650 mmHg
Timer Maximum can be set up to 00.01 minutes
Minimum can be set up to 99.59 min
Vacuum setting level Vacuum can stabilize to the set value +5 mmHg within 90 secs
Power requirement 230V. 50Hz
Power 300 VA
Dimension
( W x L x H)
396 x 245 x 228

LT-101P

Features
  • Meets USP and package specifications
  • Ideal for checking leakage of packed strips, blisters, small sachets and ampoules
  • Programmable vacuum level and hold time
  • Slow venting for better results
  • Validation report printout
  • Oil-less vacuum pump
  • 5.7 inch graphical touch screen display
  • Tolerance range setting to give pass / fail results
  • Programmable 50 methods and storage of 50 product data
  • Ideal for checking leakage of packed strips, blisters, small sachets and ampoules
Specifications
Model ELT-201
Vacuum setting level Vacuum can stabilize to the set value +5 mm of Hg within 30 secs
Vacuum level 2mm Hg 650 of Hg
Timer Maximum can be set up to 99 minutes
Minimum can be set up to 1 min
Power requirement 230V. 50 Hz
Power 300 VA
Dimension
( W x L x H)
377 x 248 x 264